EasyManua.ls Logo

Sekonic LITEMASTER PRO - Equipment, Tools, and Materials for Repair

Sekonic LITEMASTER PRO
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
1. Equipment, tools and materials required for repair
1. Calibration box
The attachment to light box for L-478 incident lightfor L-478 only
2. Master exposure meter
3. Digital multi-meter (capable of measuring voltage, current and resistance)
4. Power supply box or Constant voltage power supply (capable of varying voltage, current and resistance)
for L-478 only
Calibration voltage: 2.4V+/-0.01V3.0V+/-0.01V
Confirmation voltage:2.1V+/-0.01V2.23V+/-0.01V2.33V+/-0.01V2.4V+/-0.01V2.6V+/-0.01V
*1 All voltage should be the terminal voltage values at the time of exposure meter ON.
*2 Current capacity : 0.5A and more
5.Torque Driver : Phillips(+) /#1, general tools,
Dummy batteryfor L-478 only
6.
IC-use soldering iron and solder (Pb Free Wire Solder Sn3.0Ag0.5Cu)
M705 SENJU METAL INDUSTRY Co., Ltd., or equivalent.
7. Blower brush, Nonwoven cloth
8.
Gloves
9. Adhesive : 1) DB1600B Diabond Industry Co., Ltd., product or equivalent
: 2) Super-X No.8008,CEMEDINE CO., LTD. product or equivalent
:3) Type KE-45_1 RTV Rubber, Shin-Etsu Chemical Co., Ltd product or equivalent.
10. Grease : G501 Shin-Etsu Chemical Co., Ltd., product or equivalent
11. Screw lock : 1401B Three Bond Co., Ltd., product or equivalent
12. Windows PC(for L-758 Maintenance Control)
Required OS :
Microsoft Windows XP Service Pack3 or Later.
or Microsoft Windows VISTA Service Pack2 or Later.
or Microsoft Windows 7 Service Pack1 or Later.
Recommended OS :
Microsoft Windows 7 Service Pack1 or Later.
Required Memory :
256MB (Recommended 512MB)
Required Hard disk :
100MB
Remarks : Please warn security enough
13. CD supplied by SEKONIC
L-478 Maintenance Tools
14. USB Cable (JH109001 Forward Wire Harness or equivalent: A-MiniB type)

Related product manuals