44
GB
Test mode/Disposal/Technical data
10. Test mode
In the test mode the delay times are shortened from minutes to seconds.
Switch on the test mode: Press the PROG button on the sensor for 6 seconds. The LED
will slowly flash orange.
Switch off the test mode: Press the PROG button on the sensor for 6 seconds. The test
mode will be switched off automatically after 5 minutes.
11. Disposal
The commeo Sensor WS/WSRF contains electrical components which must be dis-
posed as electronic waste.
Do not dispose the commeo Sensor WS/WSRF in your domestic waste!
To dispose the commeo Sensor WS/WSRF the laws and norms of your coun-
try have to be observed. Dispose the commeo Sensor WS/WSRF via your local
collection place for electronic old devices.
12. Technical data
Nominal voltage: 230–240 V/50–60 Hz
Standby consumption: < 0.5 W
Safety class: IP 44
Protection class: I provided the device has been properly installed
in accordance with the specifications
Permissible
ambient temperature: -25 to +55 °C
Radio frequency: 868 MHz
Dimensions: 59 x 157 x 193 mm (W x H x D without wind wheel),
Ø 138 × 157 × 237 mm (W x H x D with wind wheel),
the height corresponds to a 90° setting for the wall mounting
Type of installation: In outdoor areas on the wall or something similar
Subject to change without prior notice!
13. General declaration of conformity
SELVE GmbH & CO. KG company, hereby declares that the commeo Sensor WS/WSRF
is in conformity with the basic requirements and other relevant provisions of the Direc-
tive 2014/53/EU. The declaration of conformity can be looked up at www.selve.de.