GB
43
GB
Automatic functions/Protective functions
9.3. Twilight/Darkness (Setting only with commeo Multi Send)
Depending on the set receiver profile the sun protection system will be extended or
retracted at shortfall of the set value.
9.3.1. Receiver profile Awning
At shortfall of the set value the awning will be retracted.
9.3.2. Receiver profile Venetian blind
At shortfall of the set value the venetian blind will go down.
9.4. Manual intervention at sun automatic
When the sun protection system in automatic mode will be extended or retracted
manually, the next automatic command will only be made at modification of the light
value. At consistent light conditions there is no periodic extension or retraction sig-
nal.
9.5. Rain function (only for commeo Sensor WSRF)
Caution!
• The rain sensor is hot during operation, there is a risk of burns when
touched. Please do not touch the rain sensor in operation.
When the sensor surface is wet /moist the sun protection system will be retracted. The
sensor surface will be warmed up automatically as long as water is detected. This
provides a fast drying after the rain has stopped.
When the sun automatic is activated and the set sun threshold value will be or is
exceeded, the sun protection system will be extended automatically. When the sun
automatic is not activated, nothing will happen after the rain has stopped.
9.6. Freeze function (only for commeo Sensor WSRF)
The frost function protects the sun protection system against damages. The threshold
is settable between -15 and +5 °C with the commeo Multi Send. When temperatures
below the set frost threshold are measured, the sun protection system will no longer
extend automatically.
The setting can be made in the menu item Sensor param., the
temperature will be set by using the or buttons.
Warning!