15.9. SET UP - ADHESIVE WEIGHT
APPLICATION POSITION
The machine makes it possible for the operator to select where the adhesive weight should
be applied based on his needs. To select this configuration, proceed as described below:
- Press the key.
- use the keys to search for SEt UP
- press the key to confirm
- use the keys to search for ALU H.12 (ALU CLP – ALU H.6), using the
laser line if present
- press the key to change the setting:
TYPE OF WEIGHT
TO BE APPLIED
CONFIGURATION
SELECTED
WEIGHT APPLICATION POSITION
Traditional clip Always 12 o'clock
Adhesive
MOTORCYCLE
programme
Always 12 o'clock
Adhesive H.12
12 o'clock in all balancing programmes
Adhesive
LAS
(if applicable)
TABLE A
Adhesive CLP
using the weight-holder terminal in the
ALU1P/ALU2P balancing programmes, or
manually, taking the centre of the gripper
cavity as your reference for the midway
point of the weight, or using the 12 o'clock
position for ALU Statistics programmes
Adhesive
H.6
(failure laser)
TABLE A