Operator's Manual S 63 E - S 63 E C 79
- check and eventually act on the ultrasonic sensor support until the required distance
between the calibration template and the support itself (Fig. 6b) is reached, proceeding
as follows:
1. Fix the ultrasonic sensor calibration template in the kit using the centering accessories
on the shaft of the oscillating unit;
2. Lower the wheel guard;
CAUTION
Lowering the wheel guard enables the launch of the swinging group with the blocked
template !!!
3. Align the ultrasonic sensor calibration template to the ultrasonic sensor support and
check its distance, ie:
a. 270mm (tolerance +/- 5mm)
6a 6b
IMPORTANT: after installing the ultrasonic sensor, calibrate the sensor as described
in the paragraph “Calibrating ultrasonic width measuring sensor”.
After assembling the machine, position it in the selected place and make sure that the
6
5a