CLV640
Laser class Class 2 in accordance with EN/IEC 60825-1:2014 (identical laser class to EN/IEC
60825-1:2007). Complies with 21 CFR 1040.10 except for tolerances according to Laser
Notice no. 50 of June 24, 2007 and its following versions.
Laser power (maximum/aver‐
age)
3.2 mW / < 1.0 mW
Laser pulse duration < 300 μs
1)
Grid height approx. 15 mm at a reading distance of 200 mm
Performance
CLV640
Bar code types Code 39, code 128, code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode
Print ratio 2:1 ... 3:1
No. of codes per scan 1 ... 20 (standard decoder)
1 ... 6 (SMART decoder)
No. of codes per reading
interval
1)
1 ... 50 (auto-discriminating)
No. of characters per code/
reading interval
Max. 50 characters / max. 5,000 characters across all bar codes per reading interval, 500
characters for multiplexer function (CAN)
Number of multiple readings 1 ... 99
1)
Reading interval: The time window generated internally by the reading cycle for code detection and evaluation
Interfaces
CLV640
Serial (RS-232,
RS-422/-485)
Function: Host, AUX
Data transmission rate: 2.4 kBd ... 115.2 kBd, AUX: 57.6 kBd (RS-232)
Ethernet Function: Host, AUX
Data transmission rate: 10/100 Mbit/s, half/full duplex
Protocol: TCP/IP, EtherNet/IP, PROFINET Single Port
CAN Function: SICK CAN sensor network (master/slave, multiplexer/server)
Data transmission rate: 20 kbit/s ... 1 Mbit/s
Protocol: CSN (SICK CAN sensor network), CANopen
PROFINET PROFINET Dual Port optional over external fieldbus module CDF600-2
EtherCAT
®
Optional via external fieldbus module CDF600
PROFIBUS Optional via external fieldbus module CDF600-2
DeviceNet Optional over external connection module CDM420 + CMF fieldbus module
Digital switching inputs 2 (“Sensor 1”, “Sensor 2”), 2 additional inputs via CMC600 parameter cloning module in the
CDB650 or CDM420 connection module
Opto-decoupled, V
in
= max. 32 V, reverse polarity protected, can be wired via PNP output,
adjustable debouncing 0 ms ... 10,000 ms
Digital switching outputs 2 (“Result 1”, “Result 2”), 2 additional outputs via CMC600 parameter cloning module in the
CDB650 or CDM420 connection module
PNP, I
out
= max. 100 mA, short-circuit protected, pulse duration adjustable (static, 10 ms ...
10,000 ms)
Reading pulse Pulse sources for start: “Sensor 1” and/or “Sensor 2” switching inputs; command (data inter‐
face), auto pulse, CAN
Pulse sources for stop: reading cycle source, “Sensor 1”, “Sensor 2”, command, timer, condi‐
tion (e.g. Good Read)
Optical indicators Not accessible
Acoustic indicator None
7 TECHNICAL DATA