2 PRODUCT DESCRIPTION
2.2.3 Optional external purge air unit
The MCU control unit with integrated purge air supply cannot be used when the internal
duct pressure is greater than +2 hPa. Use the optional external purge air unit in this case. It
has a powerful blower and can be used for excess pressure in the duct up to 30 hPa. The
scope of delivery includes a purge air hose with 40 mm nominal diameter (length 5 m or
10 m).
Fig. 8: Optional external purge air unit
A weatherproof cover is available for use outdoors (see “Weatherproof covers”, page 68).
2.2.4 Voltage and purge air supply
2.2.5 Installation accessories
Separate parts of the measuring system (order separately) are:
Purge air hose with 40 mm nominal diameter for purge air supply to the sender/receiver
u
nit from the MCU-P control unit,
Connection line from the MCU to the sender/receiver unit.
Weatherproof cover
A weatherproof cover is available when using the sender/receiver unit outdoors (see
“Weatherproof covers”, page 68).
Internal duct
pressure
[hPa ]
Connection and supply components
Purge air Voltage
-50 ... +2
MCU-P + purge air hose DN40
-50... +30
Optional external purge air unit
MCU-N
We recommend using the optional external purge air unit when the sender/receiver unit
is more than 10 m away from the MCU control unit.
CAN-Bus