MAINTENANCE 5
5.3.1 Control unit MCU with integrated purge air supply
Cleaning or replacing the filter element
Open the door of the MCU with the appropriate key.
Loosen strap retainer (1) on the filter outlet and pull filter housing (2) off the connection
piec
e.
Remove the filter housing.
Rotate filter housing cover (3) in the “OPEN” arrow direction and remove the cover.
Take out the filter element and replace with a new element.
Clean the inside of the filter housing and the filter housing cover with a cloth and brush.
Insert new filter element.
Spare part: Filter element C1140, Part No. 7047560
Mount the cover on the filter housing cover and rotate opposite to the direction of the
arr
ow until it clicks into place.
Reinstall the filter housing in the control unit.
Fig. 29: Exchanging the filter element for the control unit with purge air supply
NOTICE:
For wet cleaning, use only a water-soaked cloth and then dry the parts well.
Strap retainer
Filter housing
Filter housing cover
CAN-Bus