Connection mod‐
ule
Digital switching outputs Reference
CDB650-204 “RES/OUT 1”
“RES/OUT 2”
see "Wiring the “Result 1” and
“Result 2” digital switching outputs
of the device in the CDB650-204 ",
page 116
External output 1 (“EXT. OUT 1”)
External output 2 (“EXT. OUT 2”)
see "Wiring digital switching outputs
“External output 1” and “External
output 2” of the device in the
CDB650-204", page 118
CDM420-0001 “Result 1”
“Result 2”
see "Wiring digital switching outputs
“Result 1” and “Result 2” of the
device in CDM420-0001", page 129
External output 1 (“Aux Out 1”)
External output 2 (“Aux Out 2”)
see "Wiring digital switching outputs
“External output 1” and “External
output 2” of the device in the
CDM420-0001", page 131
CDM420-0006 “Result 1”
“Result 2”
see "Wiring digital switching outputs
“Result 1” and “Result 2” of the
device in CDM420-0006", page 143
External output 1 (“Aux Out 1”)
External output 2 (“Aux Out 2”)
see "Wiring digital switching outputs
“External output 1” and “External
output 2” of the device in the
CDM420-0006", page 144
ELECTRICAL INSTALLATION 6
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
65
Subject to change without notice