NOTE
The RFU parameter description can be found on the product page.
The call is made via the SICK Product ID: pid.sick.com/{P/N}/{S/N}
{P/N} corresponds to the part number of the product, see type label.
{S/N} corresponds to the serial number of the product, see type label (if indicated).
Table 5: RFU630: Overview of product features and functions of the device
Product feature/func‐
tion
Characteristic
Safety and conven‐
ience for the customer
•
Industrial-grade, compact metal housing, CE marking (EU)
•
Automatic self-test at system start
•
Diagnostic tools for device setup and (remote) device monitoring
•
Configurable output of the read results including read diagnostics
data in two output formats
•
Operating data request. In the event of an error: output of codified
error messages on request
•
Future-proof due to firmware update via data interface
•
Future-proof SOPAS ET configuration software with password-pro‐
tected configuration mode
•
Wide supply voltage range
•
Low power consumption
•
Wide ambient temperature range, details see "Ambient data",
page 92 in the technical data
•
Parameter cloning (to back up the configuration data in the internal
device memory):
°
Externally by inserting a microSD memory card
1)
into the device
°
Externally via the CMC600
1)
parameter cloning module in the
CDB650-204
1)
or CDM420-0006
1)
connection module.
Convenient operation
and configuration
•
Configuration (online or offline) using SOPAS ET configuration soft‐
ware
•
Configuration and starting of device functions via a web server
(SOPASair) or command strings
•
Optional function blocks for easier integration of the device into PLC
programs
•
PROFINET Single Port: Configuration via GSD parameterization
•
Application-specific programming possible using the SICK AppStu‐
dio development environment.
You can find further information on the Internet at: www.sick.com/
SICK_AppStudio
•
Status and process feedback indicators via LEDs
•
2 pushbuttons on the device for executing preset functions without
connecting a computer
•
Deactivatable beeper for confirming device functioning
Reading Operation
Mode
•
Start/stop operation: For reading one or more transponders during
a read cycle
Read cycle
•
Read cycle start condition is configurable in the object trigger con‐
trol settings: digital inputs etc.
•
Read cycle stop condition is configurable in the object trigger con‐
trol settings: digital inputs etc.
Radio interface(s)
•
RFU630-131xx: One integrated antenna, up to 3 additional external
antennas can be connected
•
RFU630-041xx: Without integrated antenna, up to 4 external anten‐
nas can be connected. At least one antenna is required.
3 PRODUCT DESCRIPTION
22
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice