Table 5: RFU630: Overview of product features and functions of the device
Product feature/func‐
tion
Characteristic
Safety and conven‐
ience for the customer
Industrial-grade, compact metal housing, CE marking (EU)
Automatic self-test at system start
Diagnostic tools for device setup and (remote) device monitoring
Configurable output of the read results including read diagnostics
data in two output formats
Operating data request. In the event of an error: output of codified
error messages on request
Future-proof due to firmware update via data interface
Future-proof SOPAS ET configuration software with password-pro‐
tected configuration mode
Wide supply voltage range
Low power consumption
Wide ambient temperature range, details see "Ambient data",
page 92 in the technical data
Parameter cloning (to back up the configuration data in the internal
device memory):
°
Externally by inserting a microSD memory card
1)
into the device
°
Externally via the CMC600
1)
parameter cloning module in the
CDB650-204
1)
or CDM420-0006
1)
connection module.
Convenient operation
and configuration
Configuration (online or offline) using SOPAS ET configuration soft‐
ware
Configuration and starting of device functions via a web server
(SOPASair) or command strings
Optional function blocks for easier integration of the device into PLC
programs
PROFINET Single Port: Configuration via GSD parameterization
Application-specific programming possible using the SICK AppStu‐
dio development environment.
You can find further information on the Internet at: www.sick.com/
SICK_AppStudio
Status and process feedback indicators via LEDs
2 pushbuttons on the device for executing preset functions without
connecting a computer
Deactivatable beeper for confirming device functioning
Reading Operation
Mode
Start/stop operation: For reading one or more transponders during
a read cycle
Read cycle
Read cycle start condition is configurable in the object trigger con‐
trol settings: digital inputs etc.
Read cycle stop condition is configurable in the object trigger con‐
trol settings: digital inputs etc.
Radio interface(s)
RFU630-131xx: One integrated antenna, up to 3 additional external
antennas can be connected
RFU630-041xx: Without integrated antenna, up to 4 external anten‐
nas can be connected. At least one antenna is required.
3 PRODUCT DESCRIPTION
22
O P E R A T I N G I N S T R U C T I O N S | RFU63x 8027750//2022-12-15 | SICK
Subject to change without notice