For CDM420-0006: Adapter cable with female connector, M12, 17-pin, A-coded and male
connector, D-Sub-HD, 15-pin
â
Cable with two male connectors, TNC reverse
NOTE
As an option, two additional external digital inputs and outputs are available for the
device. Parameter cloning module CMC600, installed in the Connection Device Basic or
Connection Device Modular connection module, is required for this purpose.
The modules can be delivered as optional accessories.
For details of the characteristics of the external digital inputs and outputs, see "Wiring
digital inputs ", page 55 and see "Wiring digital outputs ", page 57.
6.3.2 RFU630-041xx without integrated antenna
Service operation
The following functions can be performed via one of the five data interfaces:
AUX 1, AUX 2, AUX 3, Host 1 or Host 2
Configuration of the device
Display of the read result of the detected transponders
Transponder access: Reading or writing data
Reading diagnostics (read result in fixed output format)
For a detailed overview, see "Use of the data interfaces", page 45.
Shown here are alternatives for the AUX interface:
AUX port of the Ethernet interface
Serial data interface
USB interface
The USB interface must only be used temporarily as a servicing interface.
SerialSerial
...
...
1
2
V
S
GND
"Ethernet" (AUX 2)
V
S
...
1 4
RFU630-
041xx
EthernetEthernet
USBUSB
"Power/Serial Data/CAN/I/O"
(AUX 1, Host 1)
"Serial RS-232" (AUX 1) 4
External antennas à
Cable 3
7
Cable 6
Cable 8Cable 9
Cable ß
1
2
Connection
module
"USB" (AUX 3),
for temporary use only 5
Configuration
Reading result
display
Transponder
access
Reading
diagnostics
SOPAS ETSOPAS ET
Computer
Figure 18: Block diagram RFU630-041xx with optional connection module: service operation,
e.g. display of read result
1
Supply voltage V
S
2
Connection module CDB650-204 or CDM420-0006
3
Null modem cable with two female connectors, D-Sub, 9-pin, both TxD and RxD crossed
4
Serial RS-232, alternative to USB or Ethernet AUX port
5
USB, alternative to serial RS-232 or Ethernet AUX port The USB interface must only be
used temporarily as a servicing interface.
6
Adapter cable with male connector, USB, type Micro-B and male connector, USB, type A
ELECTRICAL INSTALLATION 6
8027750//2022-12-15 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x
43
Subject to change without notice