5.2 Field of view diagrams
The maximum guaranteed image acquisition area in mm (inch) for each TriSpector1000
variant is shown in figure 5. The brighter areas represent typical image acquisition
areas.
56
(2.20)
60
(2.36)
75
(2.95)
H
W
65 x 15
(2.56 x 0.59)
40
(1.57)
TriSpector1008
291
(11.46)
800
(31.50)
660
(25.98)
H
W
540 x 200
(21.26 x 7.87)
180
(7.09)
TriSpector1060
141
(5.55)
400
(15.75)
330
(12.99)
H
W
270 x 100
(10.63 x 3.94)
90
(3.54)
TriSpector1030
Y
X
TriSpector1000
Y = Max. height range
X = Width at max.
working distance
Typical field of view
TriSpector1008
TriSpector1030
TriSpector1060
Figure 5: Field of view diagrams