Setting Data type Value range
Erode int 0, 10
ExcludeBorderBlobs boolean true, false
FillHoles boolean true, false
InvertBlobs boolean true, false
NumBlobsTolerance intrange 0, 250
ShowBlobMarkers boolean true, false
SortBy enum Area, X, Y
SortDirection enum Ascending, Descending
VolumeBound enum Disabled, Bottom, Plane
VolumePlaneTool PlaneRef -
VolumeTolerance realrange 0, 3000
Table 14: Edge tool
Setting Data type Value range
EdgeSide enum High, Low
EdgeThreshold real 0.1, 100
MeanDeviationTolerance realrange 0, 10
MinScoreTolerance int 0, 100
OutlierDistance real 0.01, 20
OutlierMode enum Auto, Manual
Polarity enum Any, Positive, Negative
ProbeSpacing int 1, 20
Selection enum Strongest, First, Last
Sharpness int 1, 10
Table 15: Plane tool
Setting Data type Value range
MinScoreTolerance int 0, 100
Offset real -60, 60
Percentile intrange 0, 100
Robustness int 10, 100
ShowUsedPoints boolean true, false
TiltTolerance realrange 0.0, 90.0
Table 16: Fix Plane tool
Setting Data type Value range
PositionX real -40,40
PositionY real 0, 400
PositionZ real -20, 80
XZAngle real -89, 89
YZAngle real -89, 89
Table 17: Peak tool
Setting
Data type Value range
HeightTolerance realrange -
KernelSize int 2, 6