2 Machine information 03/2013
2.3 Test series on the machine
© Siemens AG 2006-2013 All Rights Reserved
2-58 SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2013
2.3 Test series on the machine
2.3.1 Performing measurement series
Perform measurement
The following alternatives are available for performing measurements on the
machine:
Performing a single measurement with manual entry of parameters before
performing the actual test
Performance of a single measurement as the repetition of an existing
measurement without changing the parameters
Performance of a further measurement as part of a series of measurements,
based on the parameters predefined in the measurement series
Performance of a measurement of a measurement series prescribed by a
maintenance job
Performance of measurements configured in a test series
Performance measurements of a test series using a maintenance job
Performance of measurements in a test series without a machine operator, by
means of a maintenance job under the control of the PLC
Availability and privileges
Measurements, measurement series, and test series can only be performed on the
operator panel. The authorization required to perform measurements,
measurement series, and test series is described in detail in the Appendix.
Measuring procedure
The sequence is performed as follows independently of the different types of
execution and type of test:
Machine operator selects measurement, measurement series, or test series
Confirmation of the parameters of the measurement and display of the
measurement series contained in the test series
A contour test to check collision can be performed before the actual
measurement
Check release by the PLC
Machine operator sets AUTO mode and feedrate override to 100% on the
control
Machine operator presses NC START on the control
Perform machine-specific prolog of the measurement movement
Perform the measurement movement with data recording
Perform machine-specific epilog of the measurement movement
Result display
Save the result

Table of Contents

Other manuals for Siemens 6ES7 305-1BA80-0AA0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 6ES7 305-1BA80-0AA0 and is the answer not in the manual?

Siemens 6ES7 305-1BA80-0AA0 Specifications

General IconGeneral
BrandSiemens
Model6ES7 305-1BA80-0AA0
CategoryController
LanguageEnglish

Related product manuals