3.4.13 Trigger on control monitor script error
To be able to automatically check malfunctions in the configuration for defective
control monitors, you can set up the trigger on "control monitor script error".
This function is for troubleshooting only.
Each configured action, that does not provide the expected result, is signaled as a
case. This can be an access to a non-existent variable or any other incomplete
configurations.
Fig. 3-39: Trigger on script error
Function Description Type
Name Name of the trigger; can be entered by the user.
If the field remains empty or is deleted, the
system will generate a name.
If the name already exists, a consecutive
number is automatically added in parentheses.
If the name is too long, the number added can
only be seen in a tooltip.
DISPLAY
INPUT
(max. 100
characters,
all characters
are
permissible)
Log level Scripts can be monitored on
- Normal error
- Information
- Warning
- Critical error
DISPLAY
SELECTION