Siemens FDCIO223 Specifications

General IconGeneral
Product TypeI/O Module
Product type designationFDCIO223
Number of Inputs8
Number of Outputs8
Input Voltage24 VDC
Output Voltage24 VDC
Operating Voltage24 VDC
CommunicationFDnet/C-NET
Mounting TypeDIN Rail
Housing MaterialPlastic
Protection ClassIP30
Relative Humidity5 % to 95 % (non-condensing)
WeightApprox. 200 g
Output Current0.5 A per channel
Operating Temperature-20°C to +60°C

Summary

About this document

Goal and purpose

Describes the document's objective and scope for safe product use.

Target groups

Identifies intended users and their required qualifications.

Safety

2.1 Safety instructions

Details general safety notices, symbols, and hazard warnings.

2.2 Safety regulations for the method of operation

Outlines rules for electrical installations and operational safety.

2.3 Standards and directives complied with

Lists standards and directives the product adheres to.

2.4 Release Notes

Provides information on firmware version limitations and specific warnings.

Structure and function

3.1 Overview

Introduces the module's operation, features, and system integration.

3.2 Setup

Describes the module's physical components, protection, and overview diagram.

3.3 Function

Explains module functions, primary/secondary sides, and configurations.

3.4 Inputoutput configuration options (secondary side)

Shows possible configurations for inputs/outputs independently.

3.5 Diagnosis levels

Explains module self-monitoring and diagnosis levels, including error messages.

3.6 Behavior in degraded mode

Describes how the system operates when the control panel fails.

3.7 Accessories

Lists available accessories for the module.

Planning

4.1 Compatibility

Lists compatible fire detection systems.

4.2 Defining the mounting site and configuration of the lines

Guides on choosing mounting location and configuring lines.

4.3 Planning the detector line

Details parameters for detector line configuration.

4.4 Planning the control line

Details parameters for control line configuration.

4.5 Planning contact input

Details parameters for contact input configuration.

4.6 Environmental influences

Discusses factors affecting device performance in industrial settings.

4.7 Filling out the configuration sheet

Instructs on completing the configuration sheet.

Mounting Installation

5.1 Installation with housing

Provides steps for installing the module inside the FDCH221 housing.

5.2 Installation without housing

Details steps for installing the module directly onto a surface or DIN rail.

5.3 Connecting inputoutput module

Explains how to connect the module, including shielding and grounding.

Commissioning

6.1 Calibrating the control line

Explains the process of calibrating the control line.

Maintenance Repair

7.1 Status query

Describes how to check the module's status using the MC link.

7.2 Performance check

Recommends periodic checks for device operability.

Specifications

8.1 Technical data

Provides detailed technical specifications for the module.

8.2 Dimensions

Shows the physical dimensions of the module and housing.

8.3 Environmental compatibility

Discusses material composition and recycling aspects.

Annex

9.1 Collective compatibility

Lists compatible devices for Siemens/Cerberus and SynoLINE300 detector lines.

9.2 Configuration sheet

Provides templates for planning application and detector/control lines.

Index

Index

Provides an alphabetical index for document content.

Related product manuals