System Type | Modular I/O System |
---|---|
Mounting | DIN Rail |
Power Supply | 24 V DC |
Category | I/O Systems |
Protection Class | IP20 |
Modularity | Yes |
Communication Protocols | PROFINET, PROFIBUS |
Digital Inputs | Available (varies by module) |
Digital Outputs | Available (varies by module) |
Analog Inputs | Available (varies by module) |
Analog Outputs | Available (varies by module) |
Number of Modules per Station | Up to 64 |
Module Width | 15 mm, 20 mm, 22.5 mm (depending on module type) |
Describes the SIMATIC ET 200SP as a scalable and highly flexible distributed I/O system for connecting process signals.
Explains fail-safe automation systems, safety integrated concepts, and fail-safe modules and motor starters.
Illustrates the structure of a SIMATIC Safety F-system with ET 200SP and its fail-safe I/O modules.
Details the basic components of the ET 200SP distributed I/O system and its accessories.
Addresses safety extra low voltage, power supply requirements, and sensor/actuator requirements for fail-safe modules.
Provides detailed wiring rules for CPU/interface modules, BaseUnits, and motor starters, including cable cross-sections.
Covers connecting PROFINET IO and PROFIBUS DP interfaces via various BusAdapters.
Explains configuring and parameterizing the ET 200SP system using STEP 7 software.
Details how to read out the configuration, addressing, hardware identifiers, and process images.
Covers access protection, know-how protection, copy protection, and further measures for CPU security.
Details how to set up access levels, passwords, and manage CPU protection during operation.
Explains how to protect blocks and global data blocks from unauthorized access using passwords.
Details the requirements and steps for enabling configuration control for ET 200SP CPUs and interface modules.
Guides the creation of control data records for configuration control, including PLC data types and global data blocks.
Explains how to transfer the control data record to the CPU/interface module using the WRREC instruction.
Provides procedures for commissioning the ET 200SP as an IO controller, I-device, and IO device on PROFINET IO.
Details the procedures for commissioning the ET 200SP as a DP master, I-slave, and DP slave.
Covers the removal and insertion of modules and motor starters during operation, including conditions and precautions.
Explains how to update the firmware of CPUs, interface modules, I/O modules, and motor starters.
Details how to reset the CPU and interface module to factory settings using the mode selector or STEP 7.
Explains safe state principles, fault reactions, substitute value output, and reintegration of fail-safe modules.