Virtual Network configuration
 A31003-W1040-U101-1-7619, July 2006 DRAFT
136 HiPath Wireless Controller, Access Points and Convergence Software V4.0, C10/C100/C1000 User Guide
     
hwc_vnsconfiguration.fm
Authentication for a VNS
7.3.1 Vendor Specific Attributes
In addition to the standard RADIUS message, you can include Vendor Specific Attributes 
(VSAs). The Controller, Access Points and Convergence Software authentication mechanism 
provides six VSAs for RADIUS and other authentication mechanisms.
The first five of these VSAs provide information on the identify of the specific Wireless AP that 
is handling the wireless device, enabling the provision of location-based services.
The RADIUS message also includes RADIUS attributes Called-Station-Id and Calling-Station-
Id in order to include the MAC address of the wireless device.
Attribute Name ID Type Messages Description
Siemens-URL-
Redirection
1 string Returned from 
RADIUS server
A URL that can be returned to redirect a 
session to a specific Web page.
Siemens-AP-
Name 
2 string Sent to 
RADIUS server
The name of the AP the client is associating 
to. It can be used to assign policy based on 
AP name or location.
Siemens-AP-
Serial 
3 string Sent to 
RADIUS server
The AP serial number. It can be used 
instead of (or in addition to) the AP name.
Siemens-VNS-
Name
4 string Sent to 
RADIUS server
The name of the Virtual Network the client 
has been assigned to. It is used in assigning 
policy and billing options, based on service 
selection.
Siemens-SSID 5 string Sent to 
RADIUS server
The name of the SSID the client is 
associating to. It is used in assigning policy 
and billing options, based on service 
selection.
Siemens-BSS-
MAC
6 string Sent to 
RADIUS server
The name of the BSS-ID the client is 
associating to. It is used in assigning policy 
and billing options, based on service 
selection and location.
Table 6 Vendor Specific Attributes
>
Siemens-URL-Redirection is supported by MAC-based authentication.