Working with the Mitigator
Running Mitigator scans
In the Poll interval box, type (in seconds) the interval that the Analysis Engine will poll
the RF Data Collector to maintain connection status. The default is 30 seconds.
In the Poll retry count box, type the number of times the Analysis Engine will attempt
to poll the RF Data Collector to maintain connection status, before it stops sending
requests. The default is 2 attempts.
7. Click Add. The IP address of the Data Collection Engine, with its Poll Interval and Poll
Retry parameters, appears in the list.
8. To add a new collection engine, click Add Collection Engine.
9. Repeat steps 4 to 7.
10. To save your changes, click Apply.
10.3 Running Mitigator scans
The Mitigator feature allows you to view the following:
Scan Groups
Friendly APs
Third Party APs
To run the Mitigator scan task mechanism:
1. From the main menu, click Mitigator. The Mitigator screen appears.
2. Click the Scan Groups tab.
>
For each remote RF Data Collection Engine defined here, you must:
Enable it by selecting the Enable Mitigator Analysis Engine checkbox on
the remote HiPath Wireless Controller
Ensure that the controllers are routable by whatever means you use (for
example, static routes, or OSPF).
>
A scan will not run on an inactive AP, even though it appears as part of the Scan
Group. If it becomes active, it will be sent a scan request during the next periodic
scan.