EasyManua.ls Logo

Siemens Milltronics SF 500 - Page 110

Siemens Milltronics SF 500
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 104 Milltronics SF 500 - INSTRUCTION MANUAL 7ML19985CN01
mmmmm
Parameters
P358 On-line Calibration Activation
Initiates on-line calibration.
Entry:
0 = OFF
f
1 = ON
P359 Factoring
Factoring is used as a method of calculating the value of the test rate (P017) to a new test
reference. The task is performed only for the weight relevant for the multispan selected, if
applicable.
Entry:
1 = weight (
f
= 1)
Refer to
Recalibration
on page 30 for execution of the factoring procedure.
P360 Calibration Duration
Sets the number of whole calibration durations used during a zero or span calibration.
(
f
= 1 which is approximately 20 seconds.)
Enter number of time periods, range 1 to – 99.
P365 Multispan
Select the span reference to be applied for determination of rate and totalization.
Entry:
1 = multispan 1 (MS1), for product or condition A
f
2 = multispan 2 (MS2), for product or condition B
3 = multispan 3 (MS3), for product or condition C
4 = multispan 4 (MS4), for product or condition D
5 = multispan 5 (MS5), for product or condition E
6 = multispan 6 (MS6), for product or condition F
7 = multispan 7 (MS7), for product or condition G
8 = multispan 8 (MS8), for product or condition H
Refer to
Multispan
on page 38 and
P270 Auxiliary Input Function
(6) on page 100.
Note: Totalization is halted during the factoring procedure, and resumed
only upon return to the RUN mode.

Table of Contents