7ML19985CN01 Milltronics SF 500 - INSTRUCTION MANUAL Page 117
mmmmm
Parameters
P949 Diagnostic Error Testing
Enables or disables diagnostic error checking for memory, load cell LVDT conditioning
card signals. (
f
= 0)
Entry:
0 = disable
1 = enable
Refer to
Troubleshooting
on page 118.
P950 Zero Register
Registers the number of zero calibrations that have been done since the last master
reset. (
f
= 0)
P951 Span Register
Registers the number of span calibrations for the span selected, span 1 to 8 (P951 - 01 to -
08), that have been done since the last master reset. (
f
= 0)
P999 Master Reset
Resets parameters and totalizers to their factory setting. (
f
= 0)
Enter 9 to execute the reset.