4. In Diagnostic Settings section, make the changes in Auto Log Upload or Log Level.
5. Click Save.
Auto Log Upload
If Auto Log Upload is enabled, the device is going to upload all generated logs to Insights Hub
periodically. Log upload functionality for the device is enabled by default.
If Auto Log Upload is disabled, MindConnect device stops logging and uploading
log files. However, there are some third party applications that keep logging on
device. These logs will be uploaded when Auto Log Upload is enabled again.
Log Levels
Log level represents the log level of MindConnect device. There are five possible log levels, and
the hierarchy is as follows in lowest (TRACE) to highest (ERROR) priority. In TRACE mode, the
device will log extensively and in ERROR mode device will only log error messages.
The selected log level and logging mechanism works as logging only selected level and the
higher levels.
Log level is set to INFO by default.
Auto Log Level Change
TRACE/DEBUG log levels provide more verbose logs which will be helpful to
troubleshoot issues, however they produce more files. If the log level is set to
TRACE/DEBUG. It will be automatically changed to INFO after one day.
Auto log level change operation will not be synchronized with the assets device
configuration.
Overview of onboarding MindConnect IoT2040
2.6 Configuring diagnostic settings
MindConnect IoT2040
System Manual 8/2023 18