SCALANCE X-100
Operating Instructions, 12/2016, A2B00060666-08
27
Assembly
4
4.1
Safety notices for installation
Safety notices
When installing the device, keep to the safety notices listed below.
WARNING
Ambient temperature above 55 °C
If a device is operated in an ambient temperature of more than 55 °C, the temperature of
the device housing may be higher than 70 °C. The device must therefore be installed so
that it is only accessible to service personnel or users that are aware of the reason for
restricted access and the required safety measures at an ambient temperature higher than
55 °C.
WARNING
If a SCALANCE X108PoE is operated at ambient temperatures between 55 °C and 60 °C,
there must be a minimum clearance of 40 mm to neighboring modules.
Safety notices on use in hazardous areas
General safety notices relating to protection against explosion
WARNING
EXPLOSION HAZARD
Replacing components may impair suitability for Class 1, Division 2 or Zone 2.
WARNING
The device may only be operated in an environment with pollution degree 1 or 2 (see IEC
60664-1).

Other manuals for Siemens SCALANCE X-100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-100 and is the answer not in the manual?

Siemens SCALANCE X-100 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-100
CategorySwitch
LanguageEnglish

Related product manuals