13
Description of the device
3
3.1
Overview of the SCALANCE X-100
Table 3- 1 Overview of the product characteristics
Device type SCALANCE
X104-2
X106-1
X108
X108PoE
X112-2
X116
X124
SIMATIC environment
+
+
+
+
+
+
+
Diagnostics LED + + + + + + +
24 VDC
+
+
+
+
+
+
+
2 x 24 VDC + + + + + + +
Compact housing
(securing collar, etc.)
+ + + + + + +
Signaling contact + on-site oper-
ation
+ + + + + + +
Diagnostics: Web, SNMP,
PROFINET
- - - - - - -
C-PLUG
-
-
-
-
-
-
-
Ring redundancy with RM
-
-
-
-
-
-
-
Passive ring redundancy
-
-
-
-
-
-
-
Standby redundancy
-
-
-
-
-
-
-
IRT capability
-
-
-
-
-
-
-
Fast learning
-
-
-
-
-
-
-
Passive listening
-
-
-
-
-
-
-
Log table
-
-
-
-
-
-
-
SNTP + SICLOCK
-
-
-
-
-
-
-
Cut Through
-
-
-
-
-
-
-
Number of PoE ports
-
-
-
2
-
-
-
Fast learning:
Fast recognition of MAC addresses on the device that change during operation (for example,
when an end node is reconnected).
Table 3- 2 Overview of the connection options
Device type SCALANCE
X104-2
X106-1
X108
X108PoE
X112-2
X116
X124
TP (RJ-45)
Fast Ethernet 10 / 100 Mbps
4 6 8 8 12 16 24
Fiber multimode (BFOC)
Fast Ethernet 100 Mbps
2 1 - - 2 - -