Technical specifications
7.1 SCALANCE X104-2
SCALANCE X-100
44 Operating Instructions, 12/2016, A2B00060666-08
Technical specifications
Electrical data
Power supply Voltage range 18 to 32 VDC Safe Extra Low Voltage
(SELV)
Rated voltage
24 VDC
Design
4-terminal plug-in block
Signaling contact
Current
max. 100 mA
Rated voltage
24 VDC
Design
2-pin plug-in terminal block
Current consumption
Typical
160 mA
Power loss at 24 VDC
Typical
3.8 W
Overvoltage protection at input
PTC resettable fuse (0.6 A / 60 V)
Permitted ambient conditions
Ambient temperature
During operation
-10 °C to +60 °C
During storage
-40 °C to +80 °C
During transportation
-40 °C to +80 °C
Relative humidity
During operation
95 % no condensation
Operating altitude During operation 2,000 m above sea level at max. 56 °C
ambient temperature
3,000 m above sea level at max. 50 °C
ambient temperature
Design, dimensions and weight
Immunity to interference
EN 61000-6-2
Emission EN 61000-6-4
Degree of protection IP 30
MTBF (EN/IEC 61709, 40 °C)
134.87 years
Housing material
Basic housing
Die cast aluminum, powder coated
Front cover Polyphenylene ether + polystyrene
(PPE+PS plastic)
Weight
780 g
Dimensions (W x H x D)
60 x 125 x 124 mm
Installation options
Installation on a DIN rail
Installation on an S7-300 standard rail
Wall mounting
Switching properties
Aging time
30 seconds
Max. number of learnable MAC ad-
dresses
2048
Response to LLDP frames
Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q
Yes
QoS priority queues
4