2.2 Structure of PROFIBUS networks
PROFIBUS with STEP 7 V13
Function Manual, 12/2014, A5E03775446-AC
21
Area of application
You need FastConnect bus connectors for PROFIBUS for the following applications:
Connect devices with an electrical 9-pin D-Sub interface to IEC 61158-2 directly with
SIMATIC NET PROFIBUS cables.
Connect electrical segments or individual devices to the Optical Link Module (OLM) and
Optical Bus Terminal (OBT).
Connect devices or programming devices to the repeater.
Versions
The FastConnect bus connector in degree of protection IP20 is available in the following
versions:
with integrated terminating resistor and isolating function
with or without PG socket
with a cable outlet of 35°, 90° or 180°
with device category 3G suitable for zone 2 hazardous area
Figure 2-5 Example for PROFIBUS FastConnect bus connector with PG socket, cable outlet 90°