Parameter assignment/addressing
3.5 Configuring topology
PROFINET with STEP 7 V15
Function Manual, 12/2017, A5E03444486-AH
73
3.5.3
Interconnecting ports - Inspector window
Interconnecting ports in the Inspector window
To interconnect ports, follow these steps:
1. In the device or network view, select the PROFINET device or PROFINET interface.
2. In the Inspector window, navigate to the port property "Port interconnection".
When the PROFINET interface is selected, you can find this setting in the Inspector
window as follows: "Properties > General > Advanced Options > Port [...] > Port
Interconnection."
3. In the "Local port" section, you can find the settings at the local port. In the case of fiber-
optic cable you can, for example, set the cable names here.
In the "Partner port" area, select the drop-down list for "Partner port" in order to display
the available partner ports and make a selection.
Figure 3-16 Interconnecting ports in the Inspector window in STEP 7
If the PROFINET interface was disconnected, it is automatically connected by this action. In
the properties of the subnet you can set whether this subnet should or should not be used for
the networking.