EasyManua.ls Logo

Siemens SIMATIC ET 200AL - Isochronous Applications

Siemens SIMATIC ET 200AL
1585 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions
5.1 Isochronous mode
PROFIBUS with STEP 7 V13
64 Function Manual, 12/2014, A5E03775446-AC
5.1.3
Isochronous applications
Example: Isochronous measurement at several measuring points
QC requires precise measurement of dimensions within a camshaft production process.
Figure 5-2 Measuring of camshafts
Isochronous workflow
By using the system property "isochronous mode" and the associated simultaneous
measured value acquisition, measurement can be performed continuously and the time
required for measurement is reduced. Resultant workflow:
Continuous turning of the camshaft.
During the continuous turning, measure the positions and cam excursion synchronously.
Process the next camshaft.
All camshaft positions and the corresponding measured values (red) are measured
synchronously within a single rotation of the camshaft. This increases machine output and
maintains or enhances precision of the measurement.