Interrupts/diagnostic alarms
5.2 Interrupts
Digital input module DI 8x24VDC 4xM12 (6ES7141-5AF00-0BA0)
18 Manual, 02/2016, A5E36680963-AA
Meaning of the LEDs
The following tables set out the meaning of the status and error displays. Remedial
measures for diagnostic alarms can be found in section Diagnostics alarms (Page 19).
DIAG LED
Table 5- 1 Error display of the DIAG LED
DIAG LED
Meaning
Off
No supply voltage 1L+
Flashes
Module parameters not assigned
Loading firmware
(while the firmware update is being performed, all LEDs retain their cur-
rent status)
On
Module parameters assigned and no module diagnostics
Flashes
Module parameters assigned and module diagnostics
LED channel status
Table 5- 2 LED channel status display
LED channel status
Meaning
Off
Process signal = 0
On
Process signal = 1
5.2
Interrupts
The DI 8x24VDC 4xM12 digital input module supports diagnostic interrupts.
Diagnostic interrupt
The digital input module generates a diagnostic interrupt at the following events:
Short-circuit of encoder supply to ground

Table of Contents