EasyManua.ls Logo

Siemens SIMATIC ET 200AL - Page 571

Siemens SIMATIC ET 200AL
1585 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters/address space
4.2 Explanation of the parameters
Communication module CM 4xIO-Link 4xM12(6ES7147-5JD00-0BA0)
24 Manual, 10/2017, A5E32352322-AE
Port Qualifier Information (PQI)
You can enable the Port Qualifier Information (PQI) for your IO-Link master as of firmware
version V1.1.
Note
Port Qualifier Information (PQI)
If you have enabled the Port Qualifie
r Information (PQI), this information is always sent with
the size of 1 byte together with the input data of the IO
-Link device.
The following figure show the structure of the PQI byte.
You enable a parameter by setting the corresponding bit to "1".
Figure 4-1 Structure of the PQI byte
Reference
For more information, please refer to the IO-Link system
(http://support.automation.siemens.com/WW/view/en/65949252) function manual.