OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
206 Function Manual, 12/2017, A5E03735815-AF
6. A warning that the selected model is based on more than one model will appear. Click
"Yes".
This also selects the underlying model "Opc.Ua.Di.Nodset2.ua".
7. The "New Model" dialog opens.
In the example, you do not change the set values and click "Finish" to apply the values.
"http://yourorganisation.org/Demo/" is entered under "Namespace URI".
Use a meaningful namespace of your business in your project.
8. UaModeler opens the project.
Under "Information Model", right-click on "DeviceSet" and then on "Add Instance".
9. In the example, you are use strings for NodeIds.
You therefore select "String" from the drop-down list under "Additonal Attributes". If the
format for node IDs cannot be edited, check the "Enable editing of NodeIds"; the option
must be selected.
In the example, you enter "MyIMM_MES_Interface" as the node ID.
10.Select "IMM_MES_InterfaceType" from the "Type Definition" drop-down list and enter a
name for the instance.
In the example, you use the name "MyIMM_MES_Interface":
11.Click the "OK" button in the bottom right of UaModeler.