Interface module IM 155-5 MF HF (6ES7155-5MU00-0CN0)
22 Equipment Manual, 11/2023, A5E53268530-AA
Workaround for topological configuration
If you receive the "Cable length mismatch" diagnostics, perform the following workaround:
1. Accept the diagnostics. If you cannot accept the diagnostics, continue with step 2.
2. Deselect the diagnostics in your Engineering System. Alternatively, perform step 3.
3. Replace the IM 155-5 PN HF with an IM 155-5 MF HF V5.0 in the configuration.
Unsupported BusAdapters
The following BusAdapters are not supported by IM 155-5 MF HF V5.0:
BA 2xLC-LD (6ES7193-6AG50-0AA0)
BA LC-LD/RJ45 (6ES7193-6AG60-0AA0)
BA LC-LD/M12 (6ES7193-6AG70-0AA0)
3.3 Functions
3.3.1 PROFINET IO
Introduction
The interface module supports the following PROFINET IO functions:
Integrated switch with 2 ports (via BusAdapter)
Supports BusAdapter for different connection technologies to PROFINET IO
Supported Ethernet services: ping, arp, SNMP, LLDP
Port diagnostics
Deactivating ports
Isochronous real-time communication (IRT)
Minimum update time 250 μs
Device replacement without programming device
Reset to factory settings via PROFINET IO
Firmware update via PROFINET IO
Media redundancy (MRP)
Media redundancy with planned duplication (MRPD)
Shared Device with up to four IO controllers
Distribution of module channels to a maximum of 9 submodules
Module-internal or submodule-internal Shared Input/Shared Output (MSI/MSO)