EasyManua.ls Logo

Siemens SIMATIC HMI KTP400F Mobile - Page 240

Siemens SIMATIC HMI KTP400F Mobile
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
11.8 Technical specifications
Mobile Panels 2nd Generation
240 Operating Instructions, 09/2018, A5E33876626-AC
Note
Times
The specified times do not include the times of the applicable safety relay or the safety
program (PROFIsafe), including the PNIO cycle time and F
-monitoring time.
Use the following tab
le for calculation of the total reaction time: S7Safety_RTTplus.xlsm
(
https://support.industry.siemens.com/cs/#document/93839056?lc=en-US)
Safety characteristics
Safety characteristics for Mobile Panels 2nd Generation and the associated connection
boxes
In accordance with IEC 61508
Maximal attainable safety integrity level SIL2 (Proof Test Interval 1 year)
SIL3 (Proof Test Interval 1 month)
Mode of operation
High and low demand mode
Hardware fault tolerance (HFT)
1
Classification
B
Repair Time
100 h
Probability of a dangerous failure per hour (PFHd)
< 1 × 10
-8
1/h
Probability of a dangerous failure on demand (PFDavg)
< 8 × 10
-5
Mission Time
20 years
In accordance with ISO 13849-1
Meantime to Failure (MTTFd)
High
Diagnostic Coverage (DCavg)
High
Performance Level d (Proof Test Interval 1 year)
e (Proof Test Interval 1 month)
Category 3 (Proof Test Interval 1 year)
4 (Proof Test Interval 1 month)

Table of Contents

Related product manuals