Overview
1.10 Mobile Panel and connection box compatibility
Mobile Panels 2nd Generation
30 Operating Instructions, 09/2018, A5E33876626-AC
Compatibility of Mobile Panels 1st Generation connection boxes of the Mobile Panel 2nd
Generation
You can use the connection box compact, the connection box standard and the connection
box advanced with the following predecessor devices:
Mobile Panel 177 PN
Article numbers 6AV6645-0BA01-0AX0, 6AV6645-0BB01-0AX0, 6AV6645-0BC01-0AX0
Mobile Panel 277 8"
Article numbers 6AV6645-0CA01-0AX0, 6AV6645-0CB01-0AX0, 6AV6645-0CC01-0AX0
Mobile Panel 277 10"
Article number 6AV6645-0BE02-0AX0
Restrictions:
Only one hardwired system F-system with a stop function and enabling function is
permitted with a Mobile Panel 1st Generation.
PROFIsafe communication is not possible with predecessor devices, therefore a
PROFIsafe -based F-system is not feasible.
The "Mobile Panel inserted" signal is not available on the connection boxes of the Mobile
Panel 2nd Generation.
The "Control" signal is not available on the connection boxes of the Mobile Panel 2nd
Generation.