Configuring the device
5.13 Changing the password settings
Basic Panels 2nd Generation
60 Operating Instructions, 10/2016, A5E33293231-AB
5.13
Changing the password settings
Password protection prevents unauthorized access to the Start Center.
Note
The password must not contain spaces or the following special characters:
* ? . % / \ ' ".
If the password is no longer available for the Start Center, you first have to update the
operati
ng system before you can make any changes in the Start Center. All data on the HMI
device will be overwritten when you update the operating system.
Activating password protection
1.
Touch the "System Control/Info" icon.
2.
Press the "Access Protection" button.
3.
Enter a password in the "Password"
text box. Touch the text box. The
alphanumerical screen keyboard is
displayed.
4.
Confirm the password in the
"Confirm Password" text box.

Table of Contents

Other manuals for Siemens SIMATIC HMI KTP900 Basic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI KTP900 Basic and is the answer not in the manual?

Siemens SIMATIC HMI KTP900 Basic Specifications

General IconGeneral
Display Size9 inches
Display TypeTFT
Resolution800 x 480 pixels
TouchscreenYes
InterfacePROFINET
Power Supply24 V DC
Operating SystemWindows CE
USB Port1 x USB 2.0
Ambient Temperature (Operation)0 to 50 °C
Ambient Temperature (Storage)-20 to 60 °C
Relative Humidity10% to 90% (non-condensing)
Protection RatingIP65 (front)
Memory12 MB
Communication PortsEthernet (RJ45)
Number of Colors65536