Technical specifications
6.3 Power demand of the components
SIMATIC IPC127E
Operating Instructions, 01/2019, A5E44296915-AA
57
Mechanical ambient conditions
Tested in accordance with IEC 60068-2-6
Operation With wall or vertical mounting:
• 5 to 9 Hz: 3.5 mm
• 9 to 500 Hz: 9.8 m/s
2
With standard mounting rail or vertical standard mounting rail:
• 10 ... 58 Hz: 0.0375 mm
• 58 ... 200 Hz: 4.9 m/s
2
Storage/transport
• 5 to 9 Hz: 3.5 mm
• 9 to 500 Hz: 9.8 m/s
2
Tested in accordance with IEC 60068-2-27
2
2
6.3 Power demand of the components
Maximum power consumption of the auxiliary components
Maximum permitted power
consumption +5 V
5 W (for all USB devices)
Note
Device can overheat!
The power supply cannot make unlimited power available. The auxiliary components
consume energy and produce heat.
The device may overheat. The auxiliary components will be damaged.