Technical specifications
6
6.1 General technical specifications
General technical specifications
Article number
See order documents
Weight without mounting brackets
Standard: Approx. 320 g
Extended: Approx. 400 g
Supply voltage
24 V DC (19.2 to 28.8 V)
Transient voltage interruption Up to 5 ms buffer time at full load
Max. 10 events per hour; recovery time at least 1 s
Current consumption
max. 1.8 A at 24 V
Noise emission < 40 dB(A) according to DIN 45635-1
Degree of protection
IP 40 in accordance with IEC 60529
Protection class
Protection class I in accordance with IEC 61140
Degree of pollution
Device is designed for environments with pollution degree 2
Quality assurance
In accordance with ISO 9001
Note
Note the following when you operate the device according to IEC/EN/UL 61010
-2-201:
The device may only be connected to a 24 V DC power supply that meets the
requirements of safe extra-low-voltage (SELV/PELV) according to
IEC/EN/UL 61010-2-201.
In areas subject to UL / CSA 61010-2-
201, the device must be supplied with NEC Class 2
according to UL / CSA 61010-2-201 or a limited-energy circuit according to
UL / CSA 61010-1 during operation outside an enclosure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC127E and is the answer not in the manual?

Siemens SIMATIC IPC127E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC127E
CategoryIndustrial PC
LanguageEnglish

Related product manuals