Table 7- 5 Read range of the transponders III (all ranges in meters [m])
SIMATIC RF622T
1) 2)
SIMATIC RF625T
3)
SIMATIC RF630T
3)
SIMATIC RF640T
3)
SIMATIC RF615R
with internal antenna
0.4
0.3
0.3
0.4
with RF615A
0.2
0.1
0.1
0.2
with RF620A
0.2
0.1
0.2
0.2
with RF640A 0.5 0.3 0.4 0.7
with RF642A
0.9
1.0
0.5
1.4
with RF650A
0.5
0.2
0.4
0.7
with RF660A
1.0
0.8
1.0
1.2
with RF680A
0.5
0.2
0.5
1.2
SIMATIC RF650R
with RF615A
0.3
0.3
0.4
0.6
with RF620A
0.3
0.4
0.4
0.7
with RF640A
0.9
1.0
1.0
1.8
with RF642A
1.8
1.8
2.0
2.5
with RF650A
0.8
1.0
0.9
2.0
with RF660A
1.4
1.4
1.8
2.0
with RF680A
0.8
0.8
0.9
2.0
SIMATIC RF680R
with RF615A
0.4
0.5
0.5
0.8
with RF620A
0.5
0.5
0.5
1.0
with RF640A
1.2
1.4
1.4
2.5
with RF642A
1.8
1.8
2.0
4.0
with RF650A
1.0
1.4
1.2
2.5
with RF660A 1.4 1.4 1.8 3.0
with RF680A
1.2
1.2
1.2
3.0
SIMATIC RF685R
with internal antenna
1.8
2.0
2.0
3.5
with RF615A
0.4
0.5
0.5
0.8
with RF620A
0.5
0.5
0.5
1.0
with RF640A
1.2
1.4
1.4
2.5
with RF642A
1.8
1.8
2.0
4.0
with RF650A
1.0
1.4
1.2
2.5
with RF660A
1.4
1.4
1.8
3.0
with RF680A
1.2
1.2
1.2
3.0
1)
Mounting on a non-metallic surface. Mounting on metal is only permitted in combination with a spacer.
2)
With the transponder RF622T, the read/write ranges are identical. However, the read/write range of this transponder
decreases continuously from a data volume ≥ 100 bytes.
3)
Mounting on metal. Mounting surface with a minimum diameter of 150 mm, for the RF630T 300 mm.