Transponder
7.9 SIMATIC RF622T
SIMATIC RF600
390 System Manual, 11/2018, J31069-D0171-U001-A21-7618
Mechanical specifications
Can be printed using heat transfer technique
Permitted ambient conditions
• In operation, during write/read access • -25 ... +85 °C
• In operation, outside write/read access • -40 ... +85 °C
• During transportation and storage • -40 … +80 °C
Distance from metal ≥ 12 mm (with spacer)
Not suitable for mounting directly on metal
Resistance to mechanical stress
Torsion and bending stress is not permitted
Shock resistant to EN 60068-2-27
3)
Vibration to EN 60068-2-6
3)
Design, dimensions and weight
• Transponder • 120 × 30 × 6.5 mm
• Spacer • 130 × 31.5 × 12 mm
Weight
• Transponder • 14 g
• Spacer • 8 g
Type of mounting 2 x M4 screws
≤ 1 Nm
1)
In the current chip version of the transponder, the TID can be written to. It is not
recommended that you use the TID as user memory.
2)
The information relates to the maximum read range. You will find more information on
ranges in the section "Minimum distances and maximum ranges (Page 337)".
3)
The values for shock and vibration are maximum values and must not be applied
continuously.