Accessories
10.1 Wide-range power supply unit for SIMATIC RF systems
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
471
• ESD
EN 61000-6-2 / EN 61000-4-2
Contact discharge: 4 kV
• Burst
EN 61000-6-2 / EN 61 000-4-4
Symmetrical: 2 kV
• Surge
EN 61000-6-5 / EN 61 000-4-5
Symmetrical: 1 kV
• HF field
EN 61000-6-2 / EN 61000-4-3
10 V, 3 V, 1 V (80 MHz ... 2.7 GHz)
HF coupling EN 61000-6-2 / EN 61000-4-6
eff
EN 61000-6-2 / EN 61000-4-11
Design, dimensions and weights
• Without plug
140 × 85 × 35 mm
• With plug
172.7 × 85 × 35 mm
Technical specifications of the input
Rated input voltage U
in
100 to 240 VAC
Input frequency f
in
50/60 Hz
Radio interference level EN 55011/B
Connector type 7/8", 2-pin + PE
Technical specifications of the outputs
Output voltage tolerance ∆U
out
U
out nom
≤ +2 % / -1 %
at U
in
= 230 VAC, f = 50 Hz
Noise ∆U
LF
≤ 1 % U
out
Noise ∆U
HF
≤ 2 % U
out