Parameters/address space
5.7 Parameters of the digital on-board I/O
CPU 1512C-1 PN (6ES7512-1CK01-0AB0)
Manual, 12/2017, A5E40898741-AA
125
5.7
Parameters of the digital on-board I/O
Parameters of the digital on-board I/O in standard mode
You specify the properties of the digital on-board I/O during the parameter assignment with
STEP 7 (TIA Portal). The tables below list the parameters that can be set for inputs and
outputs, respectively.
When parameters are assigned in the user program, they are transferred to the digital on-
board I/O via data records with the WRREC instruction, see section Parameter assignment
and structure of the parameter data records of the digital on-board I/O (Page 175).
The use of a digital input by a technology channel
When a digital input is in use by a technology channel (HSC, PTO or PWM) the
corresponding digital input channel remains fully usable without any restriction.
Use of a digital output by a technology channel
When a digital output is in use by a technology channel (HSC, PTO or PWM) the following
restrictions apply to the use of the corresponding digital output channel:
Output values for the digital output channel are not effective. The output values are
specified by the technology channel.
The CPU STOP behavior configured for the digital output channel is not effective. The
reaction of the output to CPU Stop is specified by the technology channel.
With activated value status (Quality Information) for the DI16/DQ16 submodule, the QI-bit
for the digital output channel shows the value 0 (= Status "Bad").
The current state of the digital output is not returned to the process image output. In the
PTO operating mode, you can only observe the switching operations of the assigned
digital outputs directly at the output. In the PWM operating mode and with high-speed
counters (HSC), you can observe the current state additionally via the feedback interface.
Note, however, that high frequencies may no longer be observed under certain
circumstances due to an excessively low sampling rate.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic S7-1500 CPU 1512C-1 PN and is the answer not in the manual?

Siemens Simatic S7-1500 CPU 1512C-1 PN Specifications

General IconGeneral
Integrated InterfacesPROFINET
Data Memory1 MB
Number of Signal Boards1
Firmware VersionV2.8
Rated Value (DC)24 V
Number of PROFINET Ports2
Number of PROFINET Ports with Switch2
Integrated Web ServerYes
Number of Digital Inputs16
Number of Digital Outputs16
Number of Analog Outputs2
Number of High-speed Counters6
Program Memory300 KB
Number of Signal Modules32
Engineering withSTEP 7 Professional V13
Interface TypeEthernet
Data StorageYes
Operating Temperature0 to 60 °C
Dimensions147 mm x 129 mm