Basic Principles of Serial Data Transmission
2.8 Configuration data
CP 341 Point-to-Point Communication, Installation and Parameter Assignment
86 Manual, 09/2008, A5E02191071-01
Extended error display at the receive FB
Table 2- 10 Receive Buffer on CP (3964(R) Procedure)
Parameters Description Range of
values
Default value
Extended error display at the receive
FB
Activate the parameter "Display receive error at
FB" to also display a message frame received
with errors at the status output of the function
block P_RCV_RK.
If the parameter is deactivated, an entry is only
created in the diagnostic buffer of the CP 341.
Yes
No
No