Memory concept
6.2 Memory functions
6.2.3 CPU memory reset and restart
CPU memory reset
After the insertion/removal of a Micro Memory Card, a CPU memory reset restores defined
conditions for CPU restart (warm start).
Technology CPU:
The CPU's memory management is rebuilt.
Blocks in load memory are retained.
All runtime-related blocks are transferred from the load memory to the working memory
again.
The data blocks in the working memory are initialized (are thus reset to their initial
values).
Integrated technology of Technology CPU:
The CPU waits until the integrated technology has reached the STOP state.
The integrated technology is parameterized again.
The retentive memory of the integrated technology is rebuilt.
Any distributed I/Os connected to DP(DRIVE) are parameterized again.
The integrated technology is initialized again.
A description of the CPU memory reset procedure and its special features can be found in
chapter
CPU Memory Reset
of the S7-300 installation manual.
Warm Restart
What happens during a warm restart:
All retentive DBs retain their current values.
Non-retentive DBs are reset to their initial values.
The values of all retentive M, C, T are retained.
All non-retentive user data are initialized:
M, C, T, I, O with "0"
All run levels are initialized.
The process images are deleted.
S7-300 CPU Data: CPU 315T-2 DP
Manual, 12/2005, A5E00427933-02
6-13

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 CPU Data: CPU 315-T-2 DP and is the answer not in the manual?

Siemens SIMATIC S7-300 CPU Data: CPU 315-T-2 DP Specifications

General IconGeneral
Programming LanguageSTEP 7
Power Supply24 V DC
Number of DP masters1
Processable Technology objectsYes
Number of counters256
Number of timers256
S7 communicationYes
Number of connections for S7 communication, max.16
PG/OP communicationYes
Global data communicationYes
Integrated DP interfaceYes
Integrated PROFINET interfaceNo
SIMATIC Computing PlatformNo
Operating Temperature0 to 60 °C
Integrated InterfacesMPI, DP
CommunicationPROFIBUS DP
Cycle Time0.1 ms
Engineering withSTEP 7
Backup availableYes
Transmission rate, max.12 Mbit/s

Summary

Product Overview

Integrated technology of Technology CPU

Details the integration of technology and motion control functions within the SIMATIC CPU.

Setting up an S7-300 with a Technology CPU

Configuring

Covers configuration aspects like single-tier setup and subnets.

Status and error displays of the Technology CPU

Explains the meaning of CPU LEDs for status and error indication.

Communication with the S7-300

Communication services on the MPI/DP interface (X1)

Provides an overview of communication services like PG, OP, S7, and Global data communication.

Memory concept

Memory functions

Covers functions for generating, modifying, or deleting programs and blocks.

Cycle and response times

Cycle time

Explains the definition, calculation, and influencing factors of CPU cycle time.

Response time

Defines response time and analyzes factors affecting its variation and calculation.

Technical data

CPU 315T-2 DP

Lists detailed technical specifications for the CPU, including versions, technology objects, memory, and execution times.

Integrated Inputs/Outputs for Technology

Describes the arrangement and technical specifications of the CPU's integrated digital inputs and outputs.

Information for the Changeover to the Technology CPU

Related product manuals