SINAMICS S120 automation components
2.3 Line Modules
Connection of the SINAMICS S120 to the Technology CPU
10 Product Information, 09/2011, A5E00480378-04
2.3 Line Modules
The Line Modules perform the function of the central energy infeed for the DC link.
The following Line Modules are available:
The Active Line Module (ALM) is a self-controlled infeed/regenerative feedback unit for
creating a regulated DC link voltage. This decouples the connected Motor Modules from
the supply voltage and fluctuations within the permitted supply tolerances do not have
any effect on the motor voltage.
The Active Line Module communicates via DRIVE-CLiQ with the CU320 control unit.
The Basic Line Module (BLM) is an infeed unit that cannot actively regenerate into the
supply. This means that it can only be used for those applications in which the energy
exchange takes place between the motor- and the generator-driven axes in the DC link.
The Basic Line Module communicates via DRIVE-CLiQ with the CU320 control unit.
The Smart Line Module (SLM) is a non-regulated infeed/regenerative feedback unit with
100% regenerative continuous capability. The regenerative capability of the module can
be deactivated using a digital input.
Certain SLM types have a DRIVE-CLIQ interface (usually starting with 16 Kw).
The Smart Line Modules with DRIVE-CLIQ interface are treated like Active Line Modules
(see Interconnection of the DRIVE-CLiQ components (Page 17)). The control of the
module
s
without DRIVE-CLIQ interface must be implemented with hard wiring
(see Additional hardware wiring for Smart Line Modules without DRIVE-CLi
Q (Page 21
)).
2.4 Motor Modules
The Motor Modules operate as inverters and are available for various output currents and in
various performance classes. They obtain the energy for the motors from the DC link of the
attached Line Module.
The following Motor Module classes for controlling the motors are available for the
SINAMICS S120:
Single Motor Modules in single-axis design in booksize format
Double Motor Modules in two-axis design in booksize format

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)