EasyManuals Logo

Siemens SIMATIC S7-300 Module data Product Information

Siemens SIMATIC S7-300 Module data
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
93
Basic functions
4
4.1 Encoder settings
4.1.1 Encoder configuration (overview)
Principle
The supported encoder types depend on the device. You will find more detailed information
in the supplementary descriptions, or in the manuals for the SINAMICS S120 and the drives.
The encoder is configured in S7T Config in two stages:
1. Set the encoder type when you configure the drive.
2. Set selected dependent encoder parameters, such as number of data bits,
resolution etc. when you configure the axis.
4.1.2 Characteristic values for encoders
Encoder actual values
In the message frame between the drive and PLC, two encoder actual values are used to
transmit the encoder position - the "cyclical actual value" Gn_XIST_1
(n = 1 or 2, number of the encoder), and the "absolute actual value" Gn_XIST_2
(n = 1 or 2, number of the encoder).

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)