Expert Functions
5.6 Measuring Function
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
159
5.6.3 Fetching the measuring inputs using the TM17 terminal module
Introduction
Digital inputs for the connection to a measuring input are available at the
TM15 Terminal Module and TM17 High Feature. These can only be used for
a single measurement for the Technology CPU.
This measuring signal is used to record the current position value of an axis and which is
made available to the user program. The measuring signal is formed from a signal from the
system, e.g. using a light barrier or a Bero.
The measured actual position value is needed for tasks such as flying shears or a rotating
cutting blade.
The following section describes the configuration of a measuring input using the
TM17 terminal module.
Creating a TM17 terminal module with a measuring input
Prepare your project as described in the "Commissioning (Page 15)" chapter of this
product information so that an appropriate HW Config hardware configuration and a
NetPro network configuration are present. At least a drive and an axis must be created
in S7T Config.
For the "Measuring" function using a TM17 terminal module, a TM17 terminal module must
be integrated in the SINAMICS topology, the function of a measuring input must be created
and the PLC user program must be extended.

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)