Expert Functions
5.3 Disabling the PROFIBUS Sign-of-Life Monitoring
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
145
5.3 Disabling the PROFIBUS Sign-of-Life Monitoring
Principle
The PROFIBUS connection between the technology CPU and the SINAMICS S120 is
monitored using a sign of life. The sign-of-life monitoring is selected automatically when the
axis is created and should always be active during operation.
For diagnostic purposes, the sign-of-life monitoring can be disabled temporarily during the
commissioning.
The parameters for the sign-of-life monitoring can be selected/deselected on the Axis
technology object with "Expert list > Configuration data" or on the drive using the "p0925"
parameter.
To do this, mark "Axis_1" and select the Expert list menu command in the context menu.
Switch in the expert list to the "Configuration data" tab and to the
"\TypeOfAxis\NumberOfEncoders\Encoder_1\DriverInfo\lifeSignCheck" dialog there.
Alternatively, you can also select the Expert list > p0925 menu command in the "Drive_1"
context menu.
Sign-of-life monitoring \DriverInfo \lifeSignCheck p0925
On Yes 1
Off No 65535

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)