Basic Principles of Serial Data Transmission
2.3 Transmission integrity
Point-to-point connection CP 440 Installation and Parameter Assignment
Manual, 09/2007, A5E00057742-03
27
2.3 Transmission integrity
Introduction
Transmission integrity plays an important role in the transmission of data and in selection of
the transmission procedure. Generally speaking, the more layers of the reference model are
applied, the greater the transmission integrity.
Classifying the Supplied Protocols
The CP 440 can use the following protocols:
ASCII driver
3964(R) Procedure
The figure below illustrates how these protocols of the CP 440 fit into the ISO reference
model:
5
/D\HU
/D\HU
7KHGDWDE\WHVDUHWUDQVPLWWHGZLWK
56WDUWDQGVWRSELWVDUHDGGHG
LQWKHHYHQWRIDQHUURUWKHWUDQVPLVVLRQ
PD\EHUHSHDWHG
7KHSK\VLFDOWUDQVPLVVLRQRIWKH
GDWDE\WHVLVGHILQHG
$6&,,GULYHU
'DWDOLQNOD\HU
3K\VLFDOOD\HU
Figure 2-3 Position of the supplied protocols of the CP 440 in the reference model