Assembling the M7-400
8-40
S7-400 and M7-400 Programmable Controllers, Installation Manual
C79000-G7076-C424-01
8.7.4 Connecting a Programming Device (PG) to Two or More Nodes
Two Arrangements
To connect a programming device to two or more nodes, you must distinguish
between two arrangements:
A programming device permanently installed in the MPI subnet
A programming device connected for startup and maintenance
Depending on this, you connect the programming device to the other nodes as
follows (see also Chapter 5).
Arrangement Connection
Programming device permanently installed
in the network
Directly incorporated in the MPI subnet
Programming device connected for startup
or maintenance
Programming device connected via spur
cable to a node