4 Installing Router Kit components in the installation enclosure
4.2 Installing the Router Kit WLAN / LTE in the installation enclosure
Application example for SIMOTICS CONNECT 400 - Router KitInbetriebnahme- und Montagehandbuch 19
Blue frame
Wiring of 24 V supply voltage of SITOP compact 24V/1.3A
to SCALANCE M876-4 and to SCALANCE W774-1
Red frame
Wiring of SITOP compact 24V/1.3A with the three universal terminals
Orange frame
Attachment of LAN network cable between SCALANCE M876-4
(connection B1) and SCALANCE W774-1 (connection P1 LAN)
Green frame
Attachment of antenna cable between SCALANCE W774-1
(connection: R1 A1, R1 A2) and the two antennas ANT792-6MN
Attachment of antenna with antenna cable with SCALANCE M876-4
(connection: A1)
Result
Installation is complete.